Welcome. Click here to login.

FAQ Details

Question
What is the standard preventative maintenance cleaning procedure for the 90 Series interface pins and receptacles?
Answer
We normally do not recognize a need to clean 90 Series Contacts unless they have been placed in a harsh environment. However, if a customer wishes to clean the contacts, the proper procedure is as follows: The contacts should be sprayed with filtered air, then cleaned with isopropyl alcohol applied with a soft bristled brush, and then sprayed with filtered air again.